Reverse osmosis (RO) is a water treatment method that pushes water under pressure through a very fine membrane, which lets water through but holds back most dissolved salts. Growers use RO water as a clean, near-zero-EC starting point for mixing nutrients.
How it works
In natural osmosis, water moves through a membrane from a weak solution towards a stronger one. RO reverses this. A trade article in POWER magazine explains that hydraulic pressure is applied to the more concentrated side, forcing water through the membrane and leaving salts behind. The membrane is not perfect, so a small amount of salt still passes.
Every RO unit makes two streams:
- Permeate: the clean water you use.
- Concentrate (reject): water carrying the salts the membrane held back. It is discarded, so an RO unit always uses more water than it delivers.
Why growers use it
Tap and well water already contain dissolved salts, and the amount changes from place to place and season to season. Penn State Extension (USA) notes that irrigation water above 1.0 mS/cm may carry a high salinity risk. Starting from RO water means the EC of your tank comes almost entirely from the fertiliser you add, so recipes become repeatable.
The catch is that RO also removes useful minerals such as calcium and magnesium. Many growers add them back with a cal-mag product or blend RO water with some tap water.
Keeping the unit working
The same article warns that common polyamide membranes have very little tolerance for free chlorine. Most systems therefore run water through an activated carbon filter first, plus a sediment filter to catch particles. Filters and membranes need regular replacement and cleaning.
In Thailand and Southeast Asia
Source water can differ a lot from one farm to the next, from rainwater to hard or salty well water. Measure your source EC before deciding: if it is already low, RO may not be worth the cost and the wasted water.
Common mistakes
- Skipping the carbon pre-filter on chlorinated tap water. Chlorine damages the membrane.
- Using pure RO water without adding calcium and magnesium. Plants can show deficiencies.
- Never checking output EC. A worn membrane lets more salt through; measure permeate EC monthly.
Measure the EC of your tap or well water and of your RO output this week, and write both numbers on the unit.
Related terms
EC (Electrical Conductivity) · TDS (Total Dissolved Solids) · Cal-Mag · Nutrient Solution · Salt Buildup · pH Drift
Read more on Asiannabis
- Irrigation water for living soil: reverse osmosis, fluoride, testing your source and choosing water in Thailand (Part 2)
- Irrigation water for living soil: chlorine, chloramine, hard water and softened water (Part 1)